Solar T70 Gas Turbine, ISO Rating: 7965 Kwe, 4160 Volt 60Hz, with a Rentech Heat Recovery Steam Generator (HRSG), 200 PSIG MAWP
Solar T70 Gas Turbine, ISO Rating: 7965 Kwe, 4160 Volt 60Hz, with a Rentech Heat Recovery Steam Generator (HRSG), 200 PSIG MAWP Maximum Steaming Capacity 31,500 lb/hr, with Ancillary Equipment. This package provides an excellent opportunity for facilities seeking reliable combined heat and power (CHP) equipment without new equipment lead times.
Cogeneration Package Includes
??Solar T70 Gas Turbine
??Ideal Electric Brushless Synchronous Generator
??Generator coupling
??Solar Turbotronic Controls
??Fire & Gas Detection System
??Lube oil system
??Air inlet system
??Exhaust system
??HRSG
??Exhaust stack
??Electrical control cabinets
??Associated instrumentation
??Auxiliary equipment
Used Solar Turbines Taurus 70 Cogeneration Package. Manufactured in 2016, this unit is site rated 6,500 kW at 4,160 VAC and is equipped with a Hyundai Ideal Electric 8,125 kVA Brushless Synchronous Generator, Solar Turbotronic Control System, Det-Tronics Fire & Gas Detection, and Rentech Heat Recovery Steam Generator (HRSG).
Gas Turbine
Manufacturer: Solar Turbines
Model: Taurus 70 Gas Turbine Generator Set
Year: 2016
Serial No.: TG16724
ISO Rating: 7965 Kwe @ 15 deg. C, Sea Level
Heat Rate: 9955 Btu/Kwe-hr
Site Rating: 6400 Kwe
Turbine Speed: 15,200 RPM
Fuel: Natural Gas
Nominal Fuel Flow: 67.78MM Btu/hr
S.O. No.: 3-3X161
Generator
Ideal Electric Brushless Alternator
8,125 kVA, 6,500 kW (Site Rating), 4160 Volt, 60 Hz, .8 Power Factor, with PMA Brushless Exciter
Controls
Solar Turbotronic Controls
Det-Tronics Eagle Quantum Premier fire & gas safety system
Modern PLC/control cabinets
Heat Recovery
Rentech HRSG: Built 2016
200 PSIG MAWP Maximum steaming capacity 31,500 lb/hr, Heating surface 2,447 sq. ft.
Scope of Supply
Solar Taurus70 Gas Turbine
Ideal Electric Generator
Generator Coupling
Solar Turbotronic Controls
Fire & Gas Detection System
Lube Oil System
Air Inlet System
Exhaust System
HRSG
Exhaust Stack
Electrical Control Cabinets
Associated Instrumentation
Auxiliary Equipment
Equipment descriptions and specifications are believed to be accurate based on currently available information. Final scope of supply and specifications are subject to change following a detailed on-site inventory and inspection.
Price on serious request with named end user country
#perr