SOLAR OUR OFFER
Offer # 495838, subject to prior sale.
CHP Plant with Gas Turbine package Solar Titan 130, 11 MW, WHRB and 7 MW steam turbine. Gas fired.
1.1 Turbine engine:
Manufacturer: Solar Turbines INC, San Diego USA
Model: Titan 130 with Solonox combustion,
Packager: Turbomach
Yoc package: 2005
Operating hours: about 15.500 (whole plant), 150 starts
Was operated until 2007, after that standby
Condition: fully serviced by Turbomach and ready for start.
Capacity: 11.840 kW
Speed: 11.215 RPM continual
Fuel: Natural Gas with input pressure of 28 bar
Fuel /gas consumption: around 3.700 Nm³/h (cal.value 10,4 kWh/m³)
Burners: 14
Start system: Electro.hydraulic, 110 kW
Outlet temperature: 486°C
Exhaust gas volume: 131.000m³/h
Dimensions: longitudinal-and transverse-force bases
Turbine: 9m x 2,2m x 2,8m = 33 tons
Strainer: 4m x 2,9m x 3,8m = 4,8 tons
Insulating dome: 9m x 2,2m x 3,25m = 7 tons
Mounting : On steel skid ( with acoustic enclosure)
1.2. Reduction Gearbox
Type : Solar Epicyclic Reduction Gearbox
Output rpm : 1500
Year Manufactured : 2005
1.3. Generator
Manufacturer : Leroy Somer
Type / Model : LSA 58 BMCL 14-4P.
Frequency : 50 Hz
Voltage : 5.25 kV
Power : 14.800 kVA, PF = 0.8
Speed : 1500
Year manufactured : 2005
2. Fire protection system
3. Control systems turbine
Turbomach TTS3
Offer 495838 - Titan 130 - CHP - 2016, page 1 of 2
4. Auxiliaries
Lubrication System Fuel System
Start System electro-hydraulic 110 kW Air inlet system, 1 stage air filter system Exhaust system complete with silencer
5. Waste Heat Recovery Boiler
Manufacturer:
IEG, Livice (Slovakia)
Type:
Natural circulation boiler with additional firing
2 modules of finned tubes
Steam with add.burner:
44,5 t/h, max. 47 t/h
- 58 bar, 510°C,
O2 14,8%
Steam without add.burner 18,5 t/h
- 58 bar, 440°C,
O2 15,7%
Burner:
3 burners with 730 Nm³ each at full load
Fuel:
Natural Gas H
Cal. Value:
10,4 kWh/m³
Gas pressure input:
3.5 bara
6. Chimney
Type
two-layered, inside stainless steel
Dimension:
40 m high, exhaust 3.8 m²
Exhaust temp.
220°C (limited with compensator)
7. Feed water system
Pumps:
30 t/h, 75 bar,
3 x 50%, one in reserve
8.1 Steam turbine
Type:
B+V, MARC2 – B10, back pressure with extraction
Live steam pressure
58 bar
60,5 bar max
Live steam temp.:
510°C
Steam quantity:
45 t/h
Extraction pressure:
21 bar
24,0 bar max
Extraction temp.:
383°C
490°C max
Extraction quantity:
7 t/h
15 t/h max
Exhaust pressure :
3 bar
4 bar max
Exhaust temp. :
180°C
262°C max
Exhaust quantity :
28 t/h
47 t/h max
Speed :
10.043 RPM
Quick closing speed:
11.047 RPM
8.2 Gearbox
8.3 Generator
Manufacturer
Leroy Somer
Voltage
5.25 kV
Frequency
50 Hz
Speed
1.500 RPM
max. 1.800 RPM
Power:
9.000 kVA
Power factor:
0.8