Wartsila 9 mw unused


Wartsila 9 mw unused

Inquire

Catalog #94203

Catagory: Plant and Equipment  -- Power Generation
Dragon's Price: CONTACT US
Date Added: April 14, 2018 01:03

Wartsila 9 mw UNUSED





Equipment list from unused Wartsila 9 mw



This is a rare opportunity complete and new and excellent price, still installed , in Europe

The below is for sale. .

The price is EURO 1.95 Million NEW as is

GENERATING SET



1. 1 engine, m. WARTSILA , type 20W32, serial



number S76363215, counter 1 hr,



yom. 2008, reference nr. A 1.1



speed: 750 rpm; suitable for HFO/LBO;



100% ISO engine load 9200 KWm 1







2 1 generator, m. WARTSILA



AVK DIG167F/8; 111 KV; 50 Hz - 750min;



11250 KVA with Pf 0,8







3 1 base frame, m. WARTSILA



fastening equipment (set) and Common



base frame







4 1 elastic mounting, m. WARTSILA



Steel springs (set)







5 1 coupling, flywheel, m. WARTSILA



Flexible coupling 1 x and Generating set



assembly







6 1 connections



Flexible hoses, bellows (set), charge air and



exhaust connection pieces







7 1 platforms



Engine maintenance platform prefabricated







Mechanical Auxillary Systems



AUXILAIRY MODULES



8 1 auxilairy modules



engine auxiliary module



engine auxiliary module with integrated



booster 1



-fuel oil filter



-fuel booster pump



-return fuel pump



-return fuel tank



-pre heating unit



-thermostatic valve jacket water system



-thermostatic valve low water temperature



system



-pressure increasing pump



-piping and insulation



-valves and gauges



-module control panel







FUEL SYSTEM



9 1 light fuel oil system



Light fuel day tank (30 m3 horizontal)



Light fuel unloading pump



Light fuel oil tank equipment



Piping and valves LFO system inside



engine hall



Piping and valves LFO system outside engine hall.







10 1 hfo / ppo fuel oil system



PPO/HFO fuel oil unloading pump unit NA



PPO/HFO fuel main storage tank (600 m3



verticle insulated, heated) NA



PPO/HFO fuel main storage tank equipment



NA



PPO/HFO transfer pump unit 1 x



PPO/HFO fuel buffer tank (13 m3,



horizontal insulated, heated) 1 x



PPO/HFO fuel buffer tank equipment 1 x



PPO/HFO fuel separator unit, Alfa Laval



SA821, 2800 ltr/hr 1 x



PPO/HFO daytank (30 m3, horizontal,



insulated, heated) 1 x



PPO/HFO daytank equipment 1 x



PPO/HFO/LFO fuel oil feeder unit 1 x



-PPO/HFO fuel feeder pump 2



-LFO fuel feeder pump 1



-automatic fuel filter 1



-manual bypass filter 1



-flow meter 1



-viscosity control unit 1



PPO/HFO return cooler (with LT cooling



waterO 1 x



Piping and valves PPO/HFO system inside



engine hall 1 x



PPO/HFO tracing and insulation inside



engine hall 1 x



Piping and valves PPO/HFO outside engine



hall 1 x



PPO/HFO tracing and insulation outside



engine hall



11 1 lubricating oil system



Lubricating oil separator unit, Alfa Laval



SA831, 2800 ltr/hr 1 x



lubricating oil unloading pump unit 1 x



lubricating oil storage tank; fresh oil (13 m3,



horizontal insulated heated 1 x



lubriacting poil tank; freash oil equipment 1



x



Lubricating oil service tank; used oil (13 m3



horizontal insulated heated) 1 x



Lubricating oil service tank equipment 1 x



Lubricating oil transfer pump (mobile) 1 x



Lubricating oil transfer pump (stationary) 1 x



piping and valves lubricating oil system



inside engien hall 1 x



Piping and valves lubriacting oil system



outside engine hall 1 x



oil mist coalescer 1 x



Lubricating oil thermostatic three-way valve



2 x







12 1 compressed air system



Starting air bottle (1000 dm3 - 30 bar



nominal) 1 x



Starting air compressor unit Sperre HL2/120



1 x



Working air compressor unit (6 bar nominal)



1 x



Piping, valves and instrumentation



compressed air system (set) 1 x



13 1 cooling system



Cooling radiator LT and HT(including super



structures) 1 x



HT cooling water expansion tank 1 x



LT cooling water expansion tank (enlarged)



1 x



Preheating unit HT cooling water circuit 1 x



Maintenance water tank unit (glycol/water) 2



x



Piping and valves maintenance water



system (set) 1 x



Piping and valves engine cooling system



inside engine hall 1 x



Piping and valves cooling water system



outside engine hall 1 x







14 1 charge air system



Charge air intake oilbath filters 2 x



Expansion bellows charge air system 2 x



Charge air silencer (45 d(B) at 200 meter) 2



x



HT charge air preheater 2 x



Ducting charge air system (set) 2 x



15 1 exhaust system



Exhaust gas silencer (45 d(B) at 200 meter)



1 x



Expansion bellows exhaust system 4 x



Ducting exhaust gas system (set insulated)



1 x



Exhaust gas branch pipe 1 x



Exhaust gas single stack pipe (19,9 meter



above zero level) including



measurement platform 1 x



STATION SUPPORT SYSTEM



16 1 oily water system



oily water transfer pump unit 1 x



Horizontal oily water tank (20 m3 insulated



and heated) 1 x



Oily water unloading pump unit 1 x



Piping and valves oily water treatment



system (set) 1 x



oily water disposal connection 1 x



17 1 potable water system



Piping and water potable water system (set)



Electrical systems



DC SYSTEM



18 1 dc system



DC system for for powerplant control



(including suply to MV switch gear) 1 x







EARTHING SYSTEM



19 1 earthing system



Safety earthing system



MAIN SWITCH GEAR



20 1 main switch gear



Main busbar 1 x



Generator cubicle cables (set) 1 x



Outgoing feeder cubicle 1 x



Station auxiliary transformer cubicle 1 x



Measuting cubicle 1 x



Generator cubicle cables (set) 1 x



Block transformer 11 to 15 KV



CT,s and VT,s on 11 KV system required for



genertor measuring & protection 1 x



Generator neutral point cable (set) 1 x



Outgoing feeder cubicle cable (setO NA



Cable terminations and cable fittings 1 x



Neutral point cubicle 1 x



STATION SERVICE SYSTEM



21 1 station service system



Station auxiliary transformer 1 x



Blackstart unit NA



low voltage switchboard 1 x



CT,s and Voltage sensing for KWh metering



in LV switchboard 2 x



Frequency converter (for HT /LT cooling



radiator) 1 x



Frequency converter (for exhaust gas boiler



back-up cooling radiator) 1 x



engine auxiliairy panel 1 x



Low voltage cables 1 x



low voltage cables (auxiliary transformer to



LV switchboard) 1 x



Cable terminations and cable fittings 1 x



A3.3 DC SYSTEM



DC system for for powerplant control



(including suply to MV switch gear) 1 x



Automation system



CABLES AND ACCESOIREES



22 1 cables and accesoires



Control and Instrumentation cables 1 x



Control cables for interconnection customer



systems 1 x



Control cables between panels and MV



board 1 x



CONTROL PANELS



23 1 control panels



Central common control panel 1 x



Central generating set control panel 1 x



Differential protection relay (for generator) 1

x

Local generating set control panel 1 x



differential protection relay (for block



transformer) NA



Protection and Control panel NA



24 1 operator,s station



WISe workstation 1 x



WISE workstation 1 x



HEAT RECOVERY SYSTEM



25 1 heat recovery system



Exhaust gas recovery heat exchanger III 1 x



Heat exchanger, hot water/exhaust gas



boiler water circuit (Ill) 1 x



Circulation pump exhaust gas boiler water



ircuit (Ill) 1 x



expansion vessel exhaust gas boiler water



circuit {Ill) 1 x



Heat exchanger (Back-up) exhuast gas



boiler water circuit (Ill) 1 x



Cooling radiator (back-up) exhaust gas



boiler water circuit (Ill) 1 x



Circulation pump back-up cooling exhaust



gas boiler water circuit (Ill) 1 x



Three way valve, back-up cooling exhaust



gas boiler water circuit (Ill) 1 x



Expansion vessel exhaust gas boiler water



circuit {Ill) 1 x



Combined heat and power susyem for hot



water generation 1 x



-Heat exchanger, hot water/lubricating oil (I)

1

-Heat exchager, hot water/HT water (II) 1



-Heat exchanger, HT water (back-up (I/II))

NA

-Threewya valve, HT water (II) 1



-Three way valve, HT water (back-up(ll)) 1



-three way valve, LT water (I) 1



-Three way valve, LT water (Back-up (I)) 1



-Three way valve, lubricating oil (I) 1



-Piping, vlaves and insulation 1



Control panel 1 x



Piping and valves hot water generation



system (set) 1 x



reference:



(I)= Circuit 1 ,LT cooling water circuit,



(II) = Circuit2 ,HT cooling water circuit,



(Ill)= Cricuit 3 ,exhaust gas boiler water



circuit,



Emission control system



EMISSION CONTRO SYSTEMS



26 1 nox contro system (500 mg/nm3 at 5% 02



dry)



Selective catalytic redution (SCR) system 1

x

Urea storage tank (60 m3, verticle insulated,



heated) 1 x



Compressed air station 1 x



Piping and valve SCR system (set) 1 x



Tools



Tools



27 1 tools



Engine maintenance tools (set) 1 x



Engine hand tools (set) 1 x



Tools for turbocharger (set) 1 x



#lion